GaN power amplifier chip
| Indicator model | frequency range | Psat | Power gain | gain flatness | Additional efficiency | Input | quiescent current | Operating Voltage | working | Chip size | Performance Standard |
| (GHz) | (dBm) | (dB) | (dB) | (%) | standing wave | (mA) | (V) | conditions | (mm×mm×mm) | ||
| NC116638C-0408P1 | 0.4-0.8 | 31.5 | 20 | ±0.5 | 24 | 2.5 | 250 | 28 | continuous wave | 2.46×1.74×0.08 | Q/AT 20997A-2012 |
| NC116650C-1116P7 | 1.1-1.6 | 38.5 | 25.5 | ±0.5 | 57 | 1.5 | 280 | 28 | continuous wave | 1.90×1.80×0.08 | Q/AT 20997A-2012 |
| NC116483C-1215P25 | 1.2-1.5 | 44 | 28 | ±0.25 | 50 | 1.5 | 1000 | 28 | Pulse | 2.64 ×2.34 ×0.08 | Q/AT 20997A-2012 |
| NC116744C-1428P6 | 1.4-2.8 | 39 | 31 | ±0.5 | 48 | 2.5 | 560 | 28 | continuous wave | 4.00×2.23×0.10 | Q/AT 20997A-2012 |
| NC116649C-1621P8 | 1.6-2.1 | 39 | 29 | ±0.5 | 58 | 2 | 350 | 28 | continuous wave | 1.76×1.60×0.08 | Q/AT 20997A-2012 |
| NC116243C-2335P18 | 2.3-3.5 | 42.6 | 32.6 | ±0.8 | 50 | 1.6 | 1000 | 28 | Pulse | 2.87 ×2.25 ×0.10 | Q/AT 20997A-2012 |
| NC116147C-2735P5 | 2.7-3.5 | 38 | 25 | ±0.5 | 47 | 2 | - | 28 | Pulse | 2.30 × 1.89 ×0.10 | Q/AT 20997A-2012 |
| NC116428C-2735P8 | 2.7-3.5 | 39.5 | 20 | ±0.5 | 46 | 1.5 | 100 | 32 | Pulse | 2.30×1.86×0.08 | Q/AT 20997A-2012 |
| NC116819C-2735P15 | 2.7-3.5 | 42 | 22 | - | 60 | 2 | 600 | 36 | continuous wave | 3.43 ×2.35 ×0.08 | Q/AT 20997A-2012 |
| NC116819C-2735P15M | 2.7-3.5 | 42 | 22 | - | 60 | 2 | 600 | 36 | continuous wave | 3.43 ×2.35 ×0.08 | Q/AT 20997A-2012 |
| NC116469C-2735P17 | 2.7-3.5 | 43 | 26 | ±0.3 | 60 | 2 | 700 | 28 | Pulse | 3.40 ×2.50 ×0.08 | Q/AT 20997A-2012 |
| NC116158C-2735P20 | 2.7-3.5 | 44 | 24 | ±0.4 | 48 | 2 | 500 | 36 | Pulse | 3.55 ×2.90 ×0.10 | Q/AT 20997A-2012 |
| NC11684C-2735P30A | 2.7-3.5 | 45 | 25 | ±0.5 | 57 | 2 | 1500 | 28 | Pulse | 2.9 ×3.44 ×0.10 | Q/AT 20997A-2012 |
| NC116451C-2735P20 | 2.7-3.5 | 43 | 23 | ±0.25 | 50 | 2 | 100 | 28 | Pulse | 2.85 ×2.90 ×0.08 | Q/AT 20997A-2012 |
| NC116480C-2735P50 | 2.7-3.5 | 47 | 23 | ±0.5 | 55 | 2 | 3100 | 28 | continuous wave | 3.40 ×4.60 ×0.08 | Q/AT 20997A-2012 |
| NC116736C-3540P40 | 3.5-4.0 | 46 | 26 | ±0.5 | 58 | 2 | 2800 | 28 | Pulse | 3.80×4.50×0.08 | Q/AT 20997A-2012 |
| NC116209C-4250P40 | 4.2-5.0 | 46 | 23 | ±0.5 | 50 | 2 | 1500 | 28 | Pulse | 3.50 ×3.80 ×0.08 | Q/AT 20997A-2012 |
| NC116630C-4452P20 | 4.4-5.2 | 43 | 22 | ±0.2 | 55 | 2 | 600 | 36 | continuous wave | 2.96×2.40×0.08 | Q/AT 20997A-2012 |
| NC116643C-4654P4 | 4.6-5.4 | 36 | 23 | ±0.5 | 57 | 2 | 200 | 28 | Pulse | 2.40 × 1.45 ×0.08 | Q/AT 20997A-2012 |
| NC116636C-4758P10 | 4.7-5.8 | 40 | 20 | ±0.5 | 61 | 2 | 300 | 28 | Pulse | 2.05 × 1.40 ×0.08 | Q/AT 20997A-2012 |
| NC116384C-506P80 | 5-6 | 49 | 26 | ±0.25 | 47 | 1.5 | 5000 | 28 | Pulse | 3.50 ×5.55 ×0.08 | Q/AT 20997A-2012 |
| NC116398C-506P35 | 5-6 | 45.5 | 25 | ±0.5 | 52 | 2 | 1100 | 28 | Pulse | 3.50 ×3.50 ×0.08 | Q/AT 20997A-2012 |
| NC116435C-506P15 | 5-6 | 42 | 25 | ±1 | 55 | 2 | 1000 | 28 | Pulse | 2.90 ×2.30 ×0.08 | Q/AT 20997A-2012 |
| NC116224C-507P40 | 5-7 | 46 | 19 | ±0.5 | 45 | 2 | 1500 | 28 | Pulse | 2.85 ×4.20 ×0.08 | Q/AT 20997A-2012 |
| NC116296C-507P12 | 5-7 | 41 | 23 | ±0.5 | 45 | 2 | 600 | 28 | Pulse | 3.50 ×2.00 ×0.08 | Q/AT 20997A-2012 |
| NC116355C-507P40 | 5-7 | 46 | 25 | ±0.5 | 50 | 2 | 1500 | 28 | Pulse | 3.40 ×4.20 ×0.08 | Q/AT 20997A-2012 |
| NC116445C-507P20 | 5-7 | 43 | 25 | ±1 | 45 | 2 | 1000 | 28 | Pulse | 3.50 ×2.00 ×0.08 | Q/AT 20997A-2012 |
| NC116305C-509P3 | 5-9 | 35 | 26 | ±0.5 | 35 | 2 | 270 | 28 | Pulse | 3.50 × 1.50 ×0.08 | Q/AT 20997A-2012 |
| NC116397C-509P40 | 5-9 | 46 | 24 | - | 45 | - | 1900 | 28 | Pulse | 3.50 ×3.80 ×0.08 | Q/AT 20997A-2012 |
| NC116770C-510P30 | 5-10 | 45 | 21 | ±0.5 | 42 | 3.5 | 1500 | 28 | Pulse | 3.50×3.40×0.08 | Q/AT 20997A-2012 |
| NC116778C-5759P5 | 5.7-5.9 | 37 | 29 | - | 58 | 2.5 | 120 | 40 | continuous wave | 3.04×1.29×0.10 | Q/AT 20997A-2012 |
| NC116702C-618A | 6-18 | 25 | 10 | ±3 | - | 1.8 | 120 | 28 | Pulse | 1.30 × 1.50 ×0.08 | Q/AT 20997A-2012 |
| NC116702C-618 | 6-18 | 27 | 9 | ±0.5 | - | 1.5 | 120 | 28 | continuous wave | 1.30×1.50×0.08 | Q/AT 20997A-2012 |
| NC116728C-618 | 6-18 | 28 | 10 | ±0.5 | - | 1.5 | 150 | 28 | continuous wave | 1.30×1.50×0.08 | Q/AT 20997A-2012 |
| NC116839C-618 | 6-18 | 28 | 10 | ±0.5 | 15 | 1.2 | 130 | 28 | continuous wave | 1.50×1.30×0.08 | Q/AT 20997A-2012 |
| NC116821C-618 | 6-18 | 28 | 10 | ±0.65 | 13 | 1.3 | 135 | 28 | continuous wave | 1.50×1.30×0.08 | Q/AT 20997A-2012 |
| NC116507C-6974P10 | 6.9-7.4 | 40.5 | 22 | ±0.25 | 56 | 2 | 480 | 24 | Pulse | 3.50 ×2.00 ×0.08 | Q/AT 20997A-2012 |
| NC116507C-6974P10M | 6.9-7.4 | 40.5 | 22 | ±0.25 | 56 | 2 | 480 | 24 | Pulse | 3.50 ×2.00 ×0.08 | Q/AT 20997A-2012 |
| NC116715C-708P100 | 7-8 | 50.3 | 21 | ±0.5 | 51 | 2.5 | 4000 | 30 | Pulse | 4.00×5.32×0.10 | Q/AT 20997A-2012 |
| NC116241C-711 | 7-11 | 29 | 20 | ±1 | 20 | 2 | 170 | 28 | Pulse | 3.00 × 1.80 ×0.10 | Q/AT 20997A-2012 |
| NC116242C-711P50 | 7-11 | 47 | 19 | ±1 | 35 | 2 | 4000 | 28 | Pulse | 3.50 ×5.30 ×0.10 | Q/AT 26998-2020 |
| NC116351C-7595P60 | 7.5-9.5 | 48 | 22 | ±0.5 | 50 | 2 | 4500 | 28 | Pulse | 4.00 ×5.10 ×0.08 | Q/AT 20997A-2012 |
| NC116626C-809P18 | 8-9 | 42.5 | 27 | ±0.3 | 60 | 2 | 300 | 28 | Pulse | 3.20 ×2.20 ×0.08 | Q/AT 20997A-2012 |
| NC116731C-810P5 | 8-10.5 | 37 | 22 | ±1 | 50 | 1.8 | 300 | 28 | Pulse | 2.30×1.50×0.08 | Q/AT 20997A-2012 |
| NC116714C-812P3 | 8-12 | 35 | 16 | ±0.5 | 44 | 2.5 | - | 24 | continuous wave | 2.00×1.50×0.08 | Q/AT 20997A-2012 |
| NC116276C-812P8 | 8-12 | 39 | 20 | ±0.3 | 38 | 1.8 | 400 | 28 | Pulse | 2.50 × 1.60 ×0.08 | Q/AT 27600-2021 |
| NC116690C-812P16 | 8-12 | 42 | 22 | 0.3 | 50 | 2 | 480 | 28 | Pulse | 2.00 ×2.50 ×0.08 | Q/AT 20997A-2012 |
| NC116295C-812P20 | 8-12 | 43 | 22 | ±0.3 | 43 | 2 | 1000 | 28 | Pulse | 2.80 ×2.00 ×0.08 | Q/AT 26982-2020 |
| NC116716C-812P25 | 8-12 | 43.5 | 21.5 | ±0.5 | 45 | 1.5 | 1100 | 28 | Pulse | 2.90×3.20×0.08 | Q/AT 20997A-2012 |
| NC116315C-812P25 | 8-12 | 44 | 22 | ±0.5 | 43 | 2 | 1500 | 28 | Pulse | 2.90 ×3.20 ×0.08 | Q/AT 20997A-2012 |
| NC116703C-812P30 | 8-12 | 45 | 24 | ±0.4 | 52 | 2 | 700 | 28 | Pulse | 2.50×2.70 ×0.08 | Q/AT 20997A-2012 |
| NC116431C-812P40 | 8-12 | 46 | 23 | ±0.5 | 45 | 2 | 2400 | 28 | Pulse | 3.20 ×3.40 ×0.08 | Q/AT 20997A-2012 |
| NC116358C-812P60 | 8-12 | 48 | 22 | ±0.5 | 40 | 2 | 3500 | 28 | Pulse | 4.00 ×5.30 ×0.80 | Q/AT 20997A-2012 |
| NC116852C-812 | 8-12 | 29 | 12 | ±0.3 | 21% | 1.4 | 150 | 24 | Pulse | 2.00 × 1.50 ×0.10 | Q/AT 20997A-2012 |
| NC116847C-812P40 | 8-12 | 46 | 23 | ±0.5 | 45 | 2 | 2200 | 28 | Pulse | 3.40 ×3.20 ×0.08 | Q/AT 20997A-2012 |
| NC116811C-815P30 | 8-15 | 45 | 23 | ±0.5 | 40 | 2:01 | 1700 | 28 | Pulse | 3.00*3.20*0.08 | Q/AT 20997A-2012 |
| NC116459C-818 | 8-18 | 25 | 8 | ±1 | - | 2 | 120 | 28 | continuous wave | 1.35 × 1.35 ×0.08 | Q/AT 20997A-2012 |
| NC116110C-8510P25 | 8.5-10.5 | 44 | 24 | - | 48 | - | 2500 | 28 | Pulse | 2.60×3.10×0.08 | Q/AT 20997A-2012 |
| NC116102C-8510P50 | 8.5-10.5 | 47 | 21 | ±0.5 | 45 | 2 | 2000 | 28 | Pulse | 4.00×5.10×0.08 | Q/AT 20997A-2012 |
| NC116399C-8510P28 | 8.5-10.5 | 44.5 | 24 | ±0.3 | 50 | 1.6 | 1000 | 28 | Pulse | 3.50 ×3.00 ×0.08 | Q/AT 20997A-2012 |
| NC116353C-8513P12 | 8.5-13 | 41 | 20 | ±0.5 | 30 | 2 | 1000 | 28 | Pulse | 3.50 ×2.00 ×0.08 | Q/AT 20997A-2012 |
| NC116268C-8516P22 | 8.5-16 | 44 | 19 | ±0.5 | 33 | 2 | 2000 | 28 | Pulse | 3.50 ×3.80 ×0.08 | Q/AT 20997A-2012 |
| NC116563C-8711P90 | 8.5-11 | 49.8 | 24.8 | ±0.25 | 50 | 2 | 5500 | 28 | Pulse | 4.00×6.00×0.08 | Q/AT 20997A-2012 |
| NC116117C-1011P50 | 10-11 | 47 | 21 | ±0.5 | 40 | 2 | 1900 | 28 | Pulse | 3.70 ×4.90 ×0.08 | Q/AT 20997A-2012 |
| NC11670C-1018 | 10-18 | 27 | 14 | ±1.5 | 13 | 2 | 170 | 28 | continuous wave | 1.78×1.44×0.10 | Q/AT 24566-2017 |
| NC116438C-1018P12 | 10-18 | 41 | 20 | ±0.25 | 30 | - | - | 28 | Pulse | 3.50 ×2.30 ×0.08 | Q/AT 20997A-2012 |
| NC11635C-1018P22 | 10-18 | 44 | 18 | - | 25 | 2 | 2000 | 28 | Pulse | 3.00×3.20×0.10 | Q/AT 20997A-2012 |
| NC116545C-1018P30 | 10-18 | 45 | 22 | ±1 | 35 | 2 | 1500 | 28 | Pulse | 3.50×2.30×0.10 | Q/AT 20997A-2012 |
| NC116124C-1113P25 | 11-13 | 44 | 20 | ±0.5 | 35 | 2.5 | 1500 | 28 | continuous wave | 4.00 ×4.10 ×0.10 | Q/AT 20997A-2012 |
| NC116269C-1113P35 | 11-13 | 45.5 | 20 | ±0.3 | 37 | 2 | 1500 | 28 | continuous wave | 4.30 ×4.35 ×0.08 | Q/AT 20997A-2012 |
| NC116808C-1214P40 | 12-14 | 46 | 21 | ±1 | 45 | 2 | 2000 | 28 | Pulse | 4.00 ×5.80 ×0.10 | Q/AT 20997A-2012 |
| NC1 16693C-1214P40 | 12-14 | 46 | 22 | ±0.5 | 45 | 2.5 | 1000 | 28 | Pulse | 4.00×5.80×0.10 | Q/AT 20997A-2012 |
| NC116146C-1217P40 | 12-17 | 46 | 22 | ±0.5 | 36 | 2 | 2700 | 28 | Pulse | 4.00 ×4.15 ×0.10 | Q/AT 20997A-2012 |
| NC116524C-1218P6 | 12-18 | 38 | 19 | ±0.5 | 35 | 2 | 800 | 28 | Pulse | 3.45 × 1.60 ×0.08 | Q/AT 20997A-2012 |
| NC116192C-1218P10 | 12-18 | 40 | 20 | ±0.5 | 30 | 2 | 900 | 28 | continuous wave | 3.57 ×2.37 ×0.08 | Q/AT 20997A-2012 |
| NC116156C-1218P30 | 12-18 | 45.5 | 23.5 | ±0.5 | 30 | 2 | 3000 | 28 | Pulse | 4.10 ×4.15 ×0.10 | Q/AT 20997A-2012 |
| NC116238C-1315P80 | 12.5-15.0 | 49 | 19 | ±0.3 | 30 | 2 | 5000 | 28 | Pulse | 4.40 ×5.30 ×0.08 | Q/AT 27417-2021 |
| NC116492C-1517P15 | 15-17 | 42 | 24 | ±0.3 | 46 | 2 | 160 | 28 | Pulse | 2.30 × 1.90 ×0.08 | Q/AT 20997A-2012 |
| NC116543C-1215P25 | 12.5-15.0 | 44 | 22 | ±0.4 | 39 | 2 | 1400 | 28 | Pulse | 3.20 ×2.85 ×0.08 | Q/AT 20997A-2012 |
| NC116550C-1314P18 | 13-14 | 42.5 | 23 | ±0.5 | 54 | 2 | 1000 | 28 | Pulse | 2.30×1.90×0.08 | Q/AT 20997A-2012 |
| NC116550C-1314P18A | 13-14 | 42.5 | 22 | ±0.5 | 46 | 2 | 1100 | 28 | continuous wave | 2.30×1.90×0.08 | Q/AT 20997A-2012 |
| NC116197C-1315P40 | 13-15 | 46 | 23 | ±0.1 | 35 | 2 | 1800 | 28 | Pulse | 4.00×4.50×0.10 | Q/AT 25851-2019 |
| NC116361C-1316P4 | 13.2-16 | 36 | 18 | ±0.5 | 40 | 2 | 62 | 28 | Pulse | 2.00 × 1.50 ×0.08 | Q/AT 20997A-2012 |
| NC116136C-1415P30 | 13.7-14.8 | 45 | 22 | ±0.2 | 35 | 2 | 2000 | 28 | continuous wave | 5.00 ×6.65 ×0.08 | Q/AT 20997A-2012 |
| NC11680C-1415P25 | 14-15 | 44 | 21 | ±1.5 | 30 | 2.5 | 2000 | 28 | continuous wave | 3.40×4.10×0.10 | Q/AT 20997A-2012 |
| NC11691C-1416P50 | 14-16 | 47 | 21 | ±0.4 | 30 | 2.5 | 4000 | 32 | Pulse | 3.50×5.00×0.08 | Q/AT 24794-2018 |
| NC116724C-1416P60 | 14-16 | 48 | 23 | ±0.3 | 47 | 2 | 4000 | 28 | Pulse | 3.30×5.00×0.10 | Q/AT 20997A-2012 |
| NC116809C-1417P2M | 14-17 | 34 | 24 | ±0.4 | 56 | 2.6 | 210 | 12 | Pulse | 2.40 × 1.15 ×0.10 | Q/AT 20997A-2012 |
| NC116809C-1417P2 | 14-17 | 34 | 24 | ±0.4 | 56 | 2.6 | 210 | 12 | Pulse | 2.40 × 1.15 ×0.10 | Q/AT 20997A-2012 |
| NC116481C-1418 | 14-18 | 26 | 17 | ±0.5 | - | 1.5 | 190 | 28 | continuous wave | 2.18 × 1.28 ×0.08 | Q/AT 20997A-2012 |
| NC11663C-1418 | 14-18 | 26 | 21 | ±1 | - | 2 | 190 | 28 | continuous wave | 2.18×1.32×0.10 | Q/AT 23870-2016 |
| NC116669C-1418P3 | 14-18 | 35 | 21 | ±1 | 40 | 2 | 185 | 28 | continuous wave | 2.18×1.15×0.10 | Q/AT 20997A-2012 |
| NC116446C-1418P4 | 14-18 | 36 | 20 | ±0.25 | 30 | 2 | 650 | 28 | Pulse | 1.34 ×2.30 ×0.08 | Q/AT 20997A-2012 |
| NC116827C-1418P5 | 14-18 | 37 | 20 | ±4 | 45 | 2.5 | 550 | 8.5 | Pulse | 2.90 ×2.55 ×0.10 | Q/AT 20997A-2012 |
| NC116348C-1418P8 | 14-18 | 39 | 20 | ±0.75 | 30 | 2 | 1100 | 28 | Pulse | 2.30 × 1.30 ×0.08 | Q/AT 20997A-2012 |
| NC116525C-1218P12A | 14-18 | 41 | 21 | ±0.5 | 38 | 2 | 1000 | 28 | Pulse | 4.00×2.70×0.08 | Q/AT 20997A-2012 |
| NC116575C-1418P30 | 14-18 | 45 | 21 | ±0.5 | 40 | 3 | 2000 | 28 | Pulse | 3.45×3.95×0.08 | Q/AT 20997A-2012 |
| NC116692C-1516P30 | 15-16 | 45 | 23 | ±0.5 | 40 | 2 | 2000 | 28 | Pulse | 3.50×4.30×0.10 | Q/AT 20997A-2012 |
| NC116824C-1418P60 | 14-18 | 48 | 24 | ±0.5 | 40 | 2 | 3300 | 28 | Pulse | 3.30 ×5.00 ×0.10 | Q/AT 20997A-2012 |
| NC116106C-1517P9 | 15-17 | 39.5 | 20 | ±0.3 | 37 | - | 200 | 28 | Pulse | 2.30×1.50×0.10 | Q/AT 24533-2018 |
| NC1 16523C-1517P60 | 15-17 | 48 | 18 | ±0.5 | 35 | 2 | 1800 | 28 | Pulse | 3.60 ×5.90 ×0.08 | Q/AT 20997A-2012 |
| NC116478C-1518P50 | 15-18 | 47 | 20 | ±0.3 | 32 | 2 | 3700 | 28 | Pulse | 3.34 ×5.00 ×0.08 | Q/AT 20997A-2012 |
| NC116159C-1518P14 | 15-18 | 41.5 | 23 | ±0.5 | 35 | 1.5 | 1500 | 28 | Pulse | 4.10 ×2.30 ×0.08 | Q/AT 25357-2019 |
| NC116732C-1517P70 | 15.5-17.5 | 48.5 | 21.5 | ±0.5 | 42 | 2.5 | 2800 | 28 | Pulse | 3.60×3.70×0.08 | Q/AT 20997A-2012 |
| NC116473C-1517P50 | 15.5-17.7 | 47 | 20 | ±0.3 | 40 | 2 | 4000 | 28 | Pulse | 3.34 ×5.00 ×0.08 | Q/AT 20997A-2012 |
| NC116700C-1518P2 | 15.5-18.0 | 34 | 24 | ±0.3 | 56 | 1.8 | 210 | 12 | Pulse | 2.40×1.15×0.10 | Q/AT 20997A-2012 |
| NC116700C-1518P2M | 15.5-18.0 | 34 | 24 | ±0.3 | 56 | 1.8 | 210 | 12 | Pulse | 2.40×1.15×0.10 | Q/AT 20997A-2012 |
| NC11613C-1618P30 | 15.5-18.0 | 45 | 20 | ±0.5 | 33 | 2.5 | 2500 | 28 | Pulse | 3.60×3.50×0.10 | Q/AT 23085-2014 |
| NC116474C-1618P25 | 15.8-17.6 | 44 | 22 | ±0.3 | 42 | 2 | 1200 | 28 | Pulse | 2.90 ×2.60 ×0.08 | Q/AT 20997A-2012 |
| NC116107C-1618P9 | 16-18 | 39.5 | 21 | ±0.3 | 36 | 2 | 200 | 28 | Pulse | 2.30×1.50×0.10 | Q/AT 20997A-2012 |
| NC116339C-1618P50 | 16-18 | 47 | 20 | ±0.5 | 35 | 2.5 | 4000 | 28 | Pulse | 3.60 ×5.90 ×0.10 | Q/AT 20997A-2012 |
| NC116262C-1718P18 | 17-18 | 42.5 | 21 | ±0.2 | 40 | 2.5 | 1300 | 28 | Pulse | 3.00×2.20×0.08 | Q/AT 20997A-2012 |
| NC116837C-1719P50 | 17-19 | 47 | 22 | ±1 | 35 | 2 | 2600 | 28 | Pulse | 3.60 ×5.90 ×0.10 | Q/AT 20997A-2012 |
| NC116462C-1720P10 | 17-20 | 41 | 23 | ±0.75 | 32 | 2.5 | 700 | 28 | continuous wave | 3.58 ×2.04 ×0.10 | Q/AT 20997A-2012 |
| NC116721C-1821P2 | 18.0-21.5 | 33 | 21 | ±0.5 | 42 | 2.5 | 155 | 20 | continuous wave | 1.85×1.27×0.10 | Q/AT 20997A-2012 |
| NC116807C-1822P25 | 18-22 | 44 | 24 | ±0.5 | 44 | 2 | 300 | 28 | continuous wave | 2.75 ×2.85 ×0.05 | Q/AT 20997A-2012 |
| NC116251C-1823P20 | 18-23 | 43 | 20 | ±0.5 | 25 | 2.5 | 2300 | 28 | Pulse | 3.70 ×3.70 ×0.08 | Q/AT 20997A-2012 |
| NC116105C-1826P7 | 18-26 | 38.5 | 11 | ±1.5 | 18 | - | - | 22 | continuous wave | 3.20×2.70×0.10 | Q/AT 20997A-2012 |
| NC116164C-1826P10 | 18-26 | 40 | 12 | ±0.5 | 20 | - | - | 22 | continuous wave | 3.20 ×3.10 ×0.08 | Q/AT 20997A-2012 |
| NC116103C-1921P20 | 19-21 | 43 | 18 | ±0.5 | 20 | 2.5 | 1500 | 28 | Pulse | 3.50×4.10×0.08 | Q/AT 25924-2019 |
| NC116740C-1922P28 | 19-22 | 44.5 | 22.5 | ±1 | 47 | 2 | 84 | 28 | Pulse | 3.00×2.85×0.05 | Q/AT 20997A-2012 |
| NC116768C-1923P20 | 19-23 | 44 | 21 | ±0.5 | 31 | 2 | 1350 | 28 | continuous wave | 3.10×2.82×0.08 | Q/AT 20997A-2012 |
| NC116722C-1922P2 | 19.5-22.0 | 33 | 23 | ±0.5 | 43 | 2 | 160 | 20 | continuous wave | 1.85×1.27×0.10 | Q/AT 20997A-2012 |
| NC116519C-1940P10 | 19-40 | 39 | 14 | ±0.75 | 14 | 2.5 | 1700 | 24 | continuous wave | 2.63 ×3.06 ×0.08 | Q/AT 20997A-2012 |
| NC116644C-2021P20 | 20-21 | 43 | 21 | ±1 | 40 | 2 | 1200 | 28 | Pulse | 2.63×2.35×0.10 | Q/AT 20997A-2012 |
| NC116711C-2126P22 | 21-26 | 43.5 | 20 | ±1 | 36 | 2.5 | 1200 | 28 | Pulse | 3.30×3.55×0.08 | Q/AT 20997A-2012 |
| NC116602C-3236P6 | 32-36 | 38 | 19 | ±0.5 | 33 | 2.5 | 500 | 24 | Pulse | 3.20 × 1.60 ×0.10 | Q/AT 20997A-2012 |
| NC116601C-3236P8 | 32-36 | 39 | 19 | ±0.5 | 31 | 2 | 550 | 24 | Pulse | 3.20 × 1.60 ×0.10 | Q/AT 20997A-2012 |
| NC116792C-3236P10 | 32-36 | 40.2 | 18.2 | ±0.5 | 31 | 2 | 1000 | 22 | Pulse | 3.50×1.60×0.08 | Q/AT 20997A-2012 |
| NC116223C-3236P20 | 32-36 | 43 | 14 | ±1 | 25 | 3 | 3100 | 22 | Pulse | 5.38 ×4.58 ×0.10 | Q/AT 20997A-2012 |
| NC116119C-3238P2 | 32-38 | 32 | 18 | ±0.5 | 25 | 2.5 | 300 | 22 | continuous wave | 3.11×1.21×0.10 | Q/AT 24674-2017 |
| NC116217C-3238P4 | 32-38 | 36.5 | 18 | ±1.6 | 26 | 2 | 480 | 22 | Pulse | 3.60 × 1.80 ×0.10 | Q/AT 20997A-2012 |
| NC116125C-3238P6 | 32-38 | 38 | 15 | ±1 | 25 | 2.5 | 1500 | 22 | Pulse | 4.70 ×2.50 ×0.10 | Q/AT 20997A-2012 |
| NC11696C-3238P12 | 32-38 | 41 | 13 | ±0.75 | 20 | 2.5 | 2000 | 22 | continuous wave | 4.67×4.42×0.10 | Q/AT 26029-2019 |
| NC116609C-3239P3 | 32-39 | 35 | 19 | ±0.5 | 36 | 2.5 | 350 | 15 | Pulse | 2.70×1.20 ×0.05 | Q/AT 20997A-2012 |
| NC11673C-3240P1 | 32-40 | 30 | 18 | ±1 | 24 | 2 | 200 | 22 | Pulse | 3.14×1.25×0.10 | Q/AT 23852-2016 |
| NC116710C-3240P2 | 32-40 | 34 | 19 | ±0.4 | 38 | 1.5 | 320 | 12 | continuous wave | 2.70×1.20×0.10 | Q/AT 20997A-2012 |
| NC116359C-3240P5 | 32-40 | 37 | 17 | ±0.75 | 25 | 2 | 500 | 22-24 | Pulse | 3.60 × 1.80 ×0.10 | Q/AT 20997A-2012 |
| NC116183C-3240P10 | 32-40 | 40 | 15 | ±0.75 | 20 | - | - | 22 | Pulse | 3.10 ×4.53 ×0.08 | Q/AT 20997A-2012 |
| NC11674C-3337P10 | 33-37 | 41.5 | 15 | ±1 | 28 | 2 | 1500 | 22 | continuous wave | 5.00 ×4.43 ×0.10 | Q/AT 20997A-2012 |
| NC11674C-3337P10A | 33-37 | 41 | 18 | ±1 | 28 | 2 | 2400 | 22 | Pulse | 3.50 ×3.00 ×0.10 | Q/AT 20997A-2012 |
| NC116508C-3337P8 | 33-37 | 39 | 17 | ±0.5 | 28 | 2 | 800 | 24 | continuous wave | 3.20 × 1.80 ×0.10 | Q/AT 20997A-2012 |
| NC116757C-3337P10 | 33-37 | 40 | 20 | ±0.5 | 38 | 2 | 180 | 15 | Pulse | 3.50×2.80×0.08 | Q/AT 20997A-2012 |
| NC116213C-3436P20 | 33.5-36 | 43 | 15 | ±0.5 | 25 | 2 | 3000 | 24 | Pulse | 4.86 ×4.44 ×0.10 | Q/AT 20997A-2012 |
| NC11672C-3436P15A | 34-36 | 41.8 | 13.8 | ±0.5 | 25 | 2.5 | 2500 | 22 | Pulse | 4.95×4.45×0.10 | Q/AT 20997A-2012 |
| NC116434C-3436P30 | 34-36 | 45 | 16 | ±0.5 | 25 | 2 | 3000 | 28 | Pulse | 3.90 ×4.50 ×0.08 | Q/AT 20997A-2012 |
| NC116522C-3436P40 | 34-36 | 46 | 14 | ±0.5 | 25 | 2 | 5000 | 28 | Pulse | 3.90 ×4.50 ×0.08 | Q/AT 20997A-2012 |
| NC116118C-3437P10 | 34.5-37.5 | 40 | 12 | ±0.75 | 25 | 2 | 2000 | 22 | Pulse | 4.88 ×4.44 ×0.10 | Q/AT 25965-2019 |
| NC116367C-4067P2 | 40-67 | 34 | 19 | ±1 | 10 | 2.5 | 1500 | 18 | Pulse | 5.10 ×3.10 ×0.05 | Q/AT 20997A-2012 |
| NC116283C-4070 | 40-70 | 25 | 20 | ±1.5 | 10 | - | 195 | 15 | continuous wave | 3.35 × 1.45 ×0.05 | Q/AT 20997A-2012 |
| NC116211C-4246P20 | 42-46 | 43 | 17 | ±0.75 | 25 | 2 | 3000 | 24 | continuous wave | 4.02 ×5.57 ×0.10 | Q/AT 20997A-2012 |
| NC116222C-4346P10 | 43-46 | 41 | 18 | ±0.5 | 30 | 2 | 1000 | 24 | continuous wave | 2.70 ×2.90 ×0.10 | Q/AT 20997A-2012 |
| NC116625C-4146P12 | 41-46 | 41 | 21 | ±0.2 | 28 | 2 | 1000 | 24 | Pulse | 2.70×2.90×0.08 | Q/AT 20997A-2012 |
| NC116751C-4550P14 | 45-50 | 41.5 | 16.5 | ±0.3 | 37 | 2.5 | 350 | 18 | Pulse | 3.60×3.70×0.05 | Q/AT 20997A-2012 |
| NC116309C-5763P3 | 57-63 | 35 | 15 | ±1.5 | 15 | 4 | 1000 | 18 | Pulse | 4.84 ×2.75 ×0.05 | Q/AT 20997A-2012 |
| NC116458C-5961P2 | 59-61 | 33 | 16 | ±0.5 | 22 | 2.5 | 700 | 15 | continuous wave | 4.84 × 1.63 ×0.05 | Q/AT 20997A-2012 |
| NC116284C-5961P5 | 59-61 | 37 | 17 | ±0.4 | 19 | 3.5 | 1300 | 18 | Pulse | 4.84 ×2.75 ×0.05 | Q/AT 20997A-2012 |
| NC116633C-6470P5 | 64-70 | 37 | 13 | ±0.5 | 20 | 2 | 1400 | 20 | Pulse | 4.21×2.66×0.05 | Q/AT 20997A-2012 |
| NC116520C-6771P4 | 67-71 | 36 | 12 | ±0.5 | 20 | 2 | 1400 | 20 | Pulse | 4.25 ×2.70 ×0.05 | Q/AT 20997A-2012 |
| NC116387C-7176P4 | 71-76 | 35.5 | 12 | ±0.5 | 18 | 2 | 1300 | 18 | Pulse | 3.90 × 1.45 ×0.05 | Q/AT 20997A-2012 |
| NC116642C-7981P1 | 79-81 | 32 | 12 | ±0.5 | 27 | 2 | 390 | 15 | Pulse | 3.70 × 1.30 ×0.05 | Q/AT 20997A-2012 |
| NC116646C-9096P1 | 90-96 | 30.5 | 12.5 | ±0.5 | 16 | 2 | 450 | 15 | Pulse/ | 3.98 × 1.32 ×0.05 | Q/AT 20997A-2012 |
| continuous wave | |||||||||||
| NC116400C-8186P2 | 81-86 | 34 | 12 | ±0.75 | 20 | 2.5 | - | - | Pulse/ | 3.00 ×5.00 ×0.05 | Q/AT 20997A-2012 |
| continuous wave | |||||||||||
| NC116699C-9296P1 | 88-98 | 29.5 | 12.5 | ±1.5 | 12 | 2.5 | 700 | 15 | Pulse | 3.75×1.25×0.05 | Q/AT 20997A-2012 |
| NC116688C-9096P2 | 90-96 | 33 | 12 | ±0.5 | 15 | 2 | 850 | 15 | Pulse | 4.30 ×2.35 ×0.05 | Q/AT 20997A-2012 |
| NC116372C-9296P4 | 92-96 | 36.5 | 13.5 | - | 10 | 2 | 1600 | 18 | Pulse | 4.33 ×4.60 ×0.05 | Q/AT 20997A-2012 |
| NC116371C-100115 | 100-115 | 28 | 15 | ±0.75 | 12 | 2.5 | 110 | 16 | continuous wave | 3.65 × 1.45 ×0.05 | Q/AT 20997A-2012 |
| NC116322C-102112 | 102-112 | 26 | 10 | ±1 | 12 | 3.5 | 110 | 16 | continuous wave | 3.65 × 1.55 ×0.05 | Q/AT 20997A-2012 |
| NC116597C-190220 | 190-220 | 17 | 4 | ±1.5 | 5 | - | - | 9 | continuous wave | 2.61 × 1.34 ×0.05 | Q/AT 20997A-2012 |